# ASKO - TDC dryers with EADBS module

Not sure which Airwallet unit you have? See [Which Airwallet unit do you have?](https://wiser.airwallet.net/en/article/which-airwallet-unit-do-you-have-t0zba1/).

For ASKO TDC dryers with the EADBS module.

# Dashboard setup
- Fixed ➜ User start time: 15 min.
- Busy signal: High

# Machine setup
- Service menu ➜ External systems ➜ Beas ➜ enabled
- Payment System (in settings): OFF

# Wiring diagram

| **No.** | **PRO310–330** | **PRO340** | **Wiring diagram** |
| --- | --- | --- | --- |
| 1 | Wire no. 1 | Wire no. 1 | Line |
| 2 | Wire no. 2 | Wire no. 2 | Neutral |
| 3 | Wire no. 3 | Wire no. 3 | +12V_In |
| 4 | Wire no. 4 | Wire no. 4 | Con (WM Status) |
| 5 | Wire no. 5 (moved to port 7) | Wire no. 8 | +12V_In |
| 6 | Wire no. 6 | Wire no. 6 | WORK (WM STATUS) |
| 7 | Wire no. 7 (moved from NC to GND) | Wire no. 7 (moved from NC to GND) | GND_In |
| 8 | No wire 8 | Wire no. 5 | Not in use |

# Inside the Airwallet unit
|| Every Airwallet unit must be opened, the PRO340 included.
- **PRO310–330:** move wire no. 5 from the AC feedback terminal to the 24V out terminal (port 7), and wire no. 7 from the NC terminal to the GND terminal.
- **PRO340 or Universal Harness:** move wire no. 7 from the NC terminal to the GND terminal. Wire no. 5 is not moved: use wire no. 8 in its place.

![](https://storage.crisp.chat/users/helpdesk/website/-/8/f/b/d/8fbd610f32d91000/image_zkvf5d.png)

# Connections
![](https://storage.crisp.chat/users/helpdesk/website/8fbd610f32d91000/diagramtdc4x_ajf4rk.png)

# Installation video
${youtube}[](FDWE4m5yCMU)