# Girbau - with vending circuit

### Recommended dashboard setup 

Fixed ➜ Pulse operated
pulse length: 500 ms., pulse repetition: 1, busy signal: High in use
 
---

### Recommended machine setup 

Enter the technician menu and set the CONF to P-to.

---

### Wiring diagram

| **No.** | **AW PRO310 or higher** | **Wiring diagram** |
| --- | --- | --- |
| 1 | Wire no. 1 | L1  - 100-240VAC + X1-1 + X1-4 vending circuit |
| 2 | Wire no. 2 | N - 100-240VAC |
| 3 | Wire no. 3 | X1-5 vending circuit |
| 4 | Wire no. 4 | N - 100-240VAC |
| 5 | Wire no. 5 | X1-2 vending circuit |
| 6 | Wire no. 6 | Not in use |
| 7 | Wire no. 7 | Not in use |


![](https://storage.crisp.chat/users/helpdesk/website/8fbd610f32d91000/girbau-with-vending-circuit-di_1r7hncf.png)