Articles on: Installations

IPSO - ILC98 no feedback



JCE020, JCE030, JCE040, JLA98, ILC98:
Fixed ➜Pulse operated
pulse length: 50 ms., pulse repetition: 1, busy signal: None




-


Wiring diagram



No.AW PRO310 or higherWiring diagram
1Wire no. 1Line
2Wire no. 2Neutral
3Wire no. 3Terminal H11-5
4Wire no. 4Not in use
5Wire no. 5Not in use
6Wire no. 6Not in use
7Wire no. 7Terminal H11-4


Updated on: 16/12/2022

Was this article helpful?

Share your feedback

Cancel

Thank you!