Articles on: Installations
This article is also available in:

ASKO - WMC Washers & TDC Dryers with EADBS module

Installation videos



Recommended dashboard setup


Fixed ➜ User start time: 15 min.


Busy signal: High



Recommended machine setup


Go into the service menu ➜ External systems ➜ Beas ➜ enabled


Make sure that Payment System from settings is OFF



Wiring diagram


No.

AW PRO310 or higher

Wiring diagram

1

Wire no. 1

Line

2

Wire no. 2

Neutral

3

Wire no. 3

+12V_In

4

Wire no. 4

Con (WM Status)

5

Wire no. 5

+12V_In

6

Wire no. 6

WORK (WM STATUS)

7

Wire no. 7

GND_In


Busy Signal Setup

__Attention: __ For Airwallet devices (PRO300 with 7 wires ONLY!) Airwallet devices with 8 wires (PRO340 or Universal Harness) Do not require this modification

 If using the BUSY signal from the machine, you MUST move wire no. 5 from port 10 to port 7 inside the Airwallet unit

Airwallet Ground Setup

This step is required for all Airwallet units

On all Airwallet units wire no. 7 must be moved internally from the NC terminal to the GND terminal in the Airwallet box.


Airwallet Installation Connections

Updated on: 08/10/2026

Was this article helpful?

Share your feedback

Cancel

Thank you!