Airwallet Box
R210 - Installation guide
Airwallet R210 Installation guides Click on the link below to go to the PDF color 29e1b4 (Download PDF)Some readersPRO310 or higher - Installation guide
Airwallet PRO310 or higher Installation guides This installation guide works for Airwallet PRO boxes from PRO310 or higher Click on the link below to go to the PDF color 29e1b4 (Download PDF)Few readersPRO300 - Installation guide
Airwallet PRO300 Installation guides Click on the link below to go to the PDF color 29e1b4 (Download PDF)Few readersPRO310 or higher - Schematic
PRO310 or higher schematic:Few readers
Electrolux professional
Electrolux - myPRO Zip Dryer
Recommended dashboard setup Fixed ➜Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Program time depends on how much the customer wishes to charge for X minutes of drying. Put the machine into Programming Mode by shorting pins 1 & 3 until the display shows dec (deicmal). Decimal Point is optional. Set C1 (Coin Value 1) to the figure of 1 Set C2 (Coin Value 2) to the figure of 0 Press the start button and the 70Few readersElectrolux - W575H with I/O type 2A card
Installation videos Recommended dashboard setup Fixed ➜Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled. Wiring diagramSome readersElectrolux - WH6-8 with I/O type 2A card
Installation videos Recommended dashboard setup With I/O type 2A card or myPROzip: Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup With I/O type 2 A card and Coin input installation: Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled. Wiring diagram |Some readersElectrolux - T5190 with I/O type 2J card
Installation videos Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled. Wiring diagramFew readersElectrolux - TD6-10 with I/O type 2J card
Installation videos Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled. Wiring diagramFew readersElectrolux - Coin input installation (No feedback)
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: None Recommended machine setup Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled. Wiring diagramFew readersElectrolux - 'Free key' installation (No feedback)
Recommended dashboard setup Fixed ➜ User start time Busy signal: None Recommended machine setup No additional setup necessary when the device is installed on the ‘free key’ Wiring diagramFew readersElectrolux - myPRO Zip Washer
Recommended dashboard setup Fixed ➜Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Put the machine into Programming Mode by shorting pins 1 & 3 until the display shows dec (deicmal). Decimal Point is optional. Set C1 (Coin Value 1) to the figure of 1 Set C2 (Coin Value 2) to the figure of 0 Set each Program to the Value of 1 End ProgrammingFew readers
Miele professional
Miele - PW5065 washer with X1/1 coin socket
Installation videos Recommended dashboard setup Fixed ➜ User start time ➜ 15 min. busy signal: End Recommended machine setup Cut the wire 1W14 on the coin socket. Detach the humidity sensor ➜ Enter the technician menu ➜ Payment system ➜ Pulse controlled. Delete paid signal ➜ Yes Wiring diagramFew readersMiele - PWM 507 washer with XCI Communication Module
Installation videos Recommended dashboard setup Fixed ➜ User start time ➜ 15 min. Busy signal: End (High can also be used, if selected in the machine setup) Recommended machine setup Payment system ➜ Programme control Feedback signal ➜ Programme end Delete paid signal ➜ Yes Wiring diagramFew readersMiele - PT5135C dryer with X1/1 coin socket
Installation videos Recommended dashboard setup Fixed ➜ User start time ➜ 15 min. busy signal: End Recommended machine setup Cut the wire 1W14 on the coin socket. Detach the humidity sensor ➜ Enter the technician menu ➜ Payment system ➜ Pulse controlled. Delete paid signal ➜ Yes Wiring diagramFew readersMiele - PDR 507 dryer with XCI Communication Module
Installation videos Recommended dashboard setup Fixed ➜ User start time ➜ 15 min. Busy signal: End (High can also be used, if selected in the machine setup) Recommended machine setup Payment system ➜ Programme control Feedback signal ➜ Programme end Delete paid signal ➜ Yes Wiring diagramFew readers
Schulthess professional
Schulthess - Topline Pro TA 9340
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 1000 ms., pulse repetition: 1, busy signal: High Recommended machine setup Go to Service function and enter the code 36/14/25 Under Machine parameters ➜ Payment options the option Jeton should be active Go to Additional functions and enter the following code 29/05/17 Under Jeton settings ➜ Parameters, Jeton should be on pulse In additional functions, assign values to each accessible machine progrFew readersSchulthess - Topline Pro 9240
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 1000 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Go to Service function and enter the code 36/14/25 Under Machine parameters ➜ Payment options the option Jeton should be active Go to Additional functions and enter the following code 29/05/17 Under Jeton settings ➜ Parameters, Jeton should be on pulse In additional functions, assign values to each accessible machine progrFew readers
IPSO professional
IPSO - ILC98 with feedback
Recommended dashboard setup JCE020, JCE030, JCE040, JLA98, ILC98: Fixed ➜ Pulse operated Pulse length: 50 ms., pulse repetition: 1, busy signal: Low Recommended machine setup Wiring diagram |Few readersIPSO - ILC98 no feedback
Recommended dashboard setup JCE020, JCE030, JCE040, JLA98, ILC98: Fixed ➜Pulse operated pulse length: 50 ms., pulse repetition: 1, busy signal: None Recommended machine setup Wiring diagramFew readersIPSO - Series HC, HD & DR with central panel
Recommended dashboard setup Series HC, HD, DR with central panel: Fixed ➜ User start time busy signal: High Recommended machine setup Wiring diagramFew readers
Fagor professional
Fagor - Concept
Installation videos Recommended dashboard setup Variable ➜ Pulse operated + Time controlled Pulse length: 200 ms., Pulse repetition: 1, Time increment: 10 min. Recommended machine setup Set the dip-switch on the machine to 111100, which correlates to 10 min increment pr. pulse. Wiring diagramFew readersFagor - Touch Plus Control
Installation videos Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readers
ASKO Professional
ASKO - WMC Washer
Installation videos Recommended dashboard setup Fixed ➜ User start time: 15 min. Busy signal: High Recommended machine setup Go into the service menu ➜ Settings ➜ Payment system ➜ Enabled ➜ External systems ➜ Beas ➜ Enabled Wiring diagramSome readersASKO - TDC Dryer
Installation videos Recommended dashboard setup Fixed ➜ User start time: 15 min. Busy signal: High Recommended machine setup Go into the service menu ➜ External systems ➜ Beas ➜ enabled Wiring diagramSome readers
Maytag
Maytag - MHN33 with busy signal
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., pulse repetition: 1, busy signal: Low in use Recommended machine setup Set the machine to vended laundry according to the installation manual. Wiring diagramFew readersMaytag - Stacked Products 100-240V supply installation
Recommended dashboard setup Fixed ➜ Pulse operated pulse length: 25 ms., pulse repetition: 1, busy signal: None If the Airwallet unit is installed on a machine that also allows for coins, then the pulse repetition must be equal to the price divided by the std. coin value. E.g. The price of a dryer is 1 £ and the machine standard coin value is 0.25 £. Therefore the pulse repetition is 4 pulses. The installation is without feedback from the machine, meaning the device will be available agFew readers
Girbau
Girbau - with vending circuit
Recommended dashboard setup Fixed ➜ Pulse operated pulse length: 500 ms., pulse repetition: 1, busy signal: High in use Recommended machine setup Enter the technician menu and set the CONF to P-to. Wiring diagramFew readersGirbau - EH020 (No feedback)
Recommended dashboard setup Fixed ➜ Pulse operated pulse length: 500 ms., pulse repetition: 1, busy signal: None Recommended machine setup Setup the machine with coin drop 1 according to the installation manual. Wiring diagramFew readers
Primer
Primer - PROFESSIONAL WASHER LP 8,10 T2
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readersPrimer - PROFESSIONAL DRYER DP 8,10P, DP-10P BASIC
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readers
DOMUS
DOMUS - HPW-8, 10
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readersDOMUS - HPD-8/10
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readers
DANUBE
DANUBE - WPR 8-10
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readersDANUBE - DRYERS DPR 8-10
Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Set the machine to credit mode in the menu. Wiring diagramFew readers
Grandimpianti
Grandimpianti - WAVY
Grandimpianti - WAVY With touch screen control Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Wiring diagramFew readersGrandimpianti - G-Wiz
Grandimpianti - G-Wiz Tumble dryers entry level. Regular electronic control Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Wiring diagramFew readersGrandimpianti - G4-Wiz
Grandimpianti - G4-Wiz Washing machines rigid mounted. Regular electronic control Recommended dashboard setup Fixed ➜ Pulse operated Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High Recommended machine setup Wiring diagramFew readers