Articles on: Installations

Electrolux - T5190 with I/O type 2J card

Installation videos





Fixed ➜ Pulse operated
Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High




Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled.



Wiring diagram


No.

AW PRO310 or higher

Wiring diagram

1

Wire no. 1

Terminal 2

2

Wire no. 2

Terminal 1

3

Wire no. 3

Terminal 19

4

Wire no. 4

Terminal 6*

5

Wire no. 5

Terminal 18

6

Wire no. 6

Not in use

7

Wire no. 7

Not in use

*Some I/O configurations expect the start signal on Terminal 5 instead of Terminal 6.


**Jumper 1 : **Terminal 2 ➜ terminal 19Jumper 2 : Terminal 1 ➜ terminal 4