Articles on: Installations

Pro340 installation guide on IPSO WE73 washer

This guide explains how to connect the Pro340 to IPSO WE73 washer.


Please disconnect machine from power whilst carrying out any work.


Pro340 wires

Pro340 wire

Name used in this guide

Wire 1

ACL

Wire 2

ACN

Wire 3

COM

Wire 4

Output NO

Wire 5

Feedback


IPSO WE73 – 16 lb washer (fitted with CPC900 totaliser)

Machine details
  • Setup: Fixed, pulse operated
  • Pulse length: 80–100 ms
  • Busy signal: High


Connect the Pro340

  1. Connect COM (wire 3) onto the totaliser terminal 2
  2. Connect Output NO (wire 4) onto the totaliser terminal 4
  3. Connect ACL (wire 1) directly onto the L input at the back of the machine
  4. Connect ACN (wire 2) directly onto the N input at the back of the machine
  5. Connect Feedback (wire 5) onto the L wire to the operating light


Totalizer Connections


Operating light for feedback


Operating light terminals


Completed install

Updated on: 12/10/2026

Was this article helpful?

Share your feedback

Cancel

Thank you!