UniMac - with feedback

Not sure which Airwallet unit you have? See Which Airwallet unit do you have?.



Fixed ➜ Pulse operated


Pulse length: 50 ms., pulse repetition: 1, busy signal: Low





Wiring diagram


No.

PRO310–330

PRO340

Wiring diagram

1

Wire no. 1

Wire no. 1

Line

2

Wire no. 2

Wire no. 2

Neutral

3

Wire no. 3

Wire no. 3

Terminal H11-5

4

Wire no. 4

Wire no. 4

Not in use

5

Wire no. 5 (moved to port 7)

Wire no. 8

Terminal H3-4

6

Wire no. 6

Wire no. 6

Terminal H3-5

7

Wire no. 7

Wire no. 7

Terminal H11-4

8

No wire 8

Wire no. 5

Not in use


PRO310–330: move wire no. 5 from port 10 to port 7 inside the Airwallet unit. PRO340: no move needed, use wire no. 8 instead.