Alliance ACA - with feedback
Recommended dashboard setup
Fixed ➜ Pulse operated
Pulse length: 80-100 ms., pulse repetition: Variable based on price of machine, busy signal: Low
Recommended machine setup
-
Wiring diagram
No. | AW PRO310 or higher | Wiring diagram |
|---|---|---|
1 | Wire no. 1 | Line |
2 | Wire no. 2 | Neutral |
3 | Wire no. 3 | Terminal H11-5 |
4 | Wire no. 4 | Not in use |
5 | Wire no. 5 | Terminal H3-4 |
6 | Wire no. 6 | Terminal H3-5 |
7 | Wire no. 7 | Terminal H11-4 |
__Attention: __
For Airwallet devices with 7 wires ONLY! 8 wire units and harnesses DO NOT APPLY
If using the BUSY signal from the machine, you MUST move wire no. 5 from port 10 to port 7 inside the Airwallet unit

NO COIN DROP INSTALLED
This setup assumes NO COIN DROP IS INSTALLED!

COIN DROP INSTALLED
You will need to bypass the coin drop directly if you are keeping the coin drop to pulse the machine correctly. This modification should be done on the machine harness directly, NOT the coin drop harness to avoid confusion if replacing the coin drop.

Tags - Speed queen, Huebsch, Ipso, Primus
Updated on: 08/04/2026
Thank you!