Articles on: Installations
This article is also available in:

Huebsch - with feedback


Fixed ➜ Pulse operated
Pulse length: 80 ms., pulse repetition: 1, busy signal: Low




If the DRYER is giving 99 minutes, you need to make sure if you are using the coin 2 connection or Airwallet harness, that you set the dEn2 to 000.25. By default the machines are programmed to $1.00.



Wiring diagram


No.

AW PRO310 or higher

Wiring diagram

1

Wire no. 1

Line

2

Wire no. 2

Neutral

3

Wire no. 3

Terminal H11-5

4

Wire no. 4

Not in use

5

Wire no. 5

Terminal H3-4

6

Wire no. 6

Terminal H3-5

7

Wire no. 7

Terminal H11-4


Attention: Move wire no. 5 from port 10 to port 7 in the Airwallet box



Updated on: 09/10/2026

Was this article helpful?

Share your feedback

Cancel

Thank you!