Pro340 installation guide on IPSO WFF185C washer
This guide explains how to connect the Pro340 to the IPSO WFF185C washer.
Pro340 wires
Pro340 wire | Name used in this guide |
|---|---|
Wire 1 | ACL |
Wire 2 | ACN |
Wire 3 | COM |
Wire 4 | Output NO |
Wire 5 | Feedback |
IPSO WFF185C – 40 lb washer (fitted with Micro-20 board)
Machine details
- Setup: Fixed, pulse operated
- Pulse length: 80–100 ms
- Busy signal: High. Taken from the door lock
Connect the Pro340
- Connect COM (wire 3) into port C on terminal block
- Connect Output NO (wire 4) into Coin 2 on terminal block
- Connect ACL (wire 1) directly onto the L input on the block
- Connect ACN (wire 2) directly onto the N input on the block
- Connect Feedback (wire 5) from the door lock
Location of terminal block behind coin mechanism
Terminal block with all connections for Pro340
Mico-20 Board for door lock connection to feedback wire 5 on Pro340
Updated on: 12/10/2026