IPSO - WFF185C washer
Not sure which Airwallet unit you have? See Which Airwallet unit do you have?.
This guide explains how to connect the Pro340 to the IPSO WFF185C washer.
Pro340 wires
Pro340 wire | Name used in this guide |
|---|---|
Wire 1 | ACL |
Wire 2 | ACN |
Wire 3 | COM |
Wire 4 | Output NO |
Wire 5 | Feedback |
IPSO WFF185C – 40 lb washer (fitted with Micro-20 board)
Machine details
- Setup: Fixed, pulse operated
- Pulse length: 80–100 ms
- Busy signal: High. Taken from the door lock
Connect the Pro340
- Connect COM (wire 3) into port C on terminal block
- Connect Output NO (wire 4) into Coin 2 on terminal block
- Connect ACL (wire 1) directly onto the L input on the block
- Connect ACN (wire 2) directly onto the N input on the block
- Connect Feedback (wire 5) from the door lock
Location of terminal block behind coin mechanism
Terminal block with all connections for Pro340
Mico-20 Board for door lock connection to feedback wire 5 on Pro340
Updated on: 12/11/2026