IPSO - WE73 washer
Not sure which Airwallet unit you have? See Which Airwallet unit do you have?.
This guide explains how to connect the Pro340 to IPSO WE73 washer.
Pro340 wires
Pro340 wire | Name used in this guide |
|---|---|
Wire 1 | ACL |
Wire 2 | ACN |
Wire 3 | COM |
Wire 4 | Output NO |
Wire 5 | Feedback |
IPSO WE73 – 16 lb washer (fitted with CPC900 totaliser)
Machine details
- Setup: Fixed, pulse operated
- Pulse length: 80–100 ms
- Busy signal: High
Connect the Pro340
- Connect COM (wire 3) onto the totaliser terminal 2
- Connect Output NO (wire 4) onto the totaliser terminal 4
- Connect ACL (wire 1) directly onto the L input at the back of the machine
- Connect ACN (wire 2) directly onto the N input at the back of the machine
- Connect Feedback (wire 5) onto the L wire to the operating light
Totalizer Connections
Operating light for feedback
Operating light terminals
Completed install
Updated on: 12/11/2026