Speed Queen WF080B with busy signal
Not sure which Airwallet unit you have? See Which Airwallet unit do you have?.
Recommended dashboard setup
Fixed ➜ Pulse operated
Pulse length: 1000 ms., pulse repetition: 1, busy signal: Low
Recommended machine setup
Wiring diagram
No. | PRO310–330 | PRO340 | Wiring diagram |
|---|---|---|---|
1 | Wire no. 1 | Wire no. 1 | Line |
2 | Wire no. 2 | Wire no. 2 | Neutral |
3 | Wire no. 3 | Wire no. 3 | Ground A2 (Blue wire) |
4 | Wire no. 4 | Wire no. 4 | Input 1 IRQ A3 (Green wire) |
5 | Wire no. 5 (moved to port 7) | Wire no. 8 | Q03 (Extension board 1) |
6 | Wire no. 6 | Wire no. 6 | Q01 (Extension board 1) |
7 | Wire no. 7 | Wire no. 7 | Not in use |
8 | No wire 8 | Wire no. 5 | Not in use |
PRO310–330: move wire no. 5 from port 10 to port 7 inside the Airwallet unit. PRO340: no move needed, use wire no. 8 instead.
Updated on: 12/11/2026