Articles on: Installations
This article is also available in:

Speed Queen Quantum Card Ready washer SWNNY2SP116

Not sure which Airwallet unit you have? See Which Airwallet unit do you have?.


Quantum Gold Card Ready washer - no feedback



NOTE: This machine type may not have the harness for coins at plug H11. The tech will need to acquire the Alliance coin harness for the specified machine. Alternately, The Airwallet Pro400 and Airwallet Alliance ACA/Quantum harness can be used instead of the factory Alliance harness.




Fixed ➜ Pulse operated
Pulse length: 80-100 ms., pulse repetition: 1, busy signal: none, occupied 25 minutes



Note: The machine has to be set to Pulse in machine settings


If the DRYER is giving 99 minutes, you need to make sure if you are using the coin 2 connection or Airwallet harness, that you set the dEn2 to 000.25. By default the machines are programmed to $1.00.


From Manual Mode (machine settings) you have to change the machine to Pulse:


(optional) PLSNod should be set to 128
PLSdEn should be set to .25 per pulse or if it is fixed amount it can be set to e.g. 3.00$


Wiring diagram

Note: There has to be added a jumper between H11-10 and H11-12 on the machine


The H11 connector is used for the start signal.


No.

PRO310–330

PRO340

Wiring diagram

1

Wire no. 1

Wire no. 1

Line

2

Wire no. 2

Wire no. 2

Neutral

3

Wire no. 3

Wire no. 3

H11 - 7

4

Wire no. 4

Wire no. 4

Not in use

5

Wire no. 5

Wire no. 5

Not in use

6

Wire no. 6

Wire no. 6

Not in use

7

Wire no. 7

Wire no. 7

H11 - 8

8

No wire 8

Wire no. 8

Not in use


Updated on: 12/11/2026