ASKO - WMC Washers & TDC Dryers with EADBS module
Installation videos
Recommended dashboard setup
Fixed ➜ User start time: 15 min.
Busy signal: High
Recommended machine setup
Go into the service menu ➜ External systems ➜ Beas ➜ enabled
Wiring diagram
No. | AW PRO310 or higher | Wiring diagram |
---|---|---|
1 | Wire no. 1 | Line |
2 | Wire no. 2 | Neutral |
3 | Wire no. 3 | +12V_In |
4 | Wire no. 4 | Con (WM Status) |
5 | Wire no. 5 | +12V_In |
6 | Wire no. 6 | WORK (WM STATUS) |
7 | Wire no. 7 | GND_In |
Attention: Move wire no. 5 from the AC-feedback terminal to the 24V-out terminal and wire no. 7 from the NC terminal to the GND terminal in the Airwallet box.
Updated on: 16/04/2024
Thank you!