Articles on: Installations

Schulthess - Topline Pro 9240



Fixed ➜ Pulse operated
Pulse length: 1000 ms., Pulse repetition: 1, Busy signal: High




Go to Service function and enter the code 36/14/25

Under Machine parameters ➜ Payment options the option Jeton should be active

Go to Additional functions and enter the following code 29/05/17

Under Jeton settings ➜ Parameters, Jeton should be on pulse

In additional functions, assign values to each accessible machine program

In the regular Settings menu, choose Automatic door opening and Anti-crease protection off


Wiring diagram



No.AW PRO310 or higherWiring diagram
1Wire no. 1ST16 - N
2Wire no. 2ST16 - L1
3Wire no. 3ST32 - 4
4Wire no. 4ST32 - 3
5Wire no. 5ST35 - 2
6Wire no. 6Not in use
7Wire no. 7Not in use


Updated on: 16/12/2022

Was this article helpful?

Share your feedback

Cancel

Thank you!