Whirlpool dryer CEM2745FQ

This type of machine is installed with a single pulse-operated terminal, which is occupied by the coin acceptor. If you want the coin acceptor to stay installed, you can use a 2-POL relay (provided by Airwallet) to make a circuit in parallel. The parallel circuit goes through the 2-POL relay and the relay is controlled by the Airwallet Pro. This is illustrated by the schematic (below).


Installation videos


Coming soon




Variable ➜ Full Duration

Time increment: 10 min., Busy signal: None




Ensure the machine is setup for coin payment.



Wiring diagram


No.

AW PRO310 or higher

Wiring diagram

1

Wire no. 1

Line terminal

2

Wire no. 2

Neutral terminal

3

Wire no. 3

Line terminal

4

Wire no. 4

Relay A1

5

Wire no. 5

Not in use

6

Wire no. 6

Not in use

7

Wire no. 7

Not in use


Jumper 1 : Neutral terminal ➜ Relay A2