Articles on: Installations

Whirlpool dryer CEM2745FQ

This type of machine is installed with a single pulse-operated terminal, which is occupied by the coin acceptor. If you want the coin acceptor to stay installed, you can use a 2-POL relay (provided by Airwallet) to make a circuit in parallel. The parallel circuit goes through the 2-POL relay and the relay is controlled by the Airwallet Pro. This is illustrated by the schematic (below).

Installation videos



Coming soon




Variable ➜ Full Duration
Time increment: 10 min., Busy signal: None




Ensure the machine is setup for coin payment.


Wiring diagram



No.AW PRO310 or higherWiring diagram
1Wire no. 1Line terminal
2Wire no. 2Neutral terminal
3Wire no. 3Line terminal
4Wire no. 4Relay A1
5Wire no. 5Not in use
6Wire no. 6Not in use
7Wire no. 7Not in use


Jumper 1 : Neutral terminal ➜ Relay A2


Updated on: 11/04/2024

Was this article helpful?

Share your feedback

Cancel

Thank you!