Electrolux - TD6-10 with I/O type 2J card
Installation videos
Recommended dashboard setup
Fixed ➜ Pulse operated
Pulse length: 500 ms., Pulse repetition: 1, Busy signal: High
Recommended machine setup
Enter service menu ➜ Price programming ➜ Set coin 1 value ➜ 1. Set Price on all programs ➜ 1 Ensure blocking start is disabled.
Wiring diagram
No. | AW PRO310 or higher | Wiring diagram |
---|---|---|
1 | Wire no. 1 | Terminal 2 |
2 | Wire no. 2 | Terminal 1 |
3 | Wire no. 3 | Terminal 19 |
4 | Wire no. 4 | Terminal 6* |
5 | Wire no. 5 | Terminal 18 |
6 | Wire no. 6 | Not in use |
7 | Wire no. 7 | Not in use |
*Some I/O configurations expect the start signal on Terminal 5 instead of Terminal 6.
Jumper 1 : Terminal 2 ➜ terminal 19
Jumper 2 : Terminal 1 ➜ terminal 4
Updated on: 11/01/2024