Maytag - MHN30PD with busy signal & coin acceptor
Recommended dashboard setup
Fixed ➜ Pulse operated
pulse length: 50 ms., pulse repetition: 1, busy signal: Low
If the Airwallet unit is installed on a machine that also allows for coins, then the pulse repetition must be equal to the price divided by the std. coin value.
E.g. The price of a dryer is 1 £ and the machine standard coin value is 0.25 £. Therefore the pulse repetition is 4 pulses.
Recommended machine setup
Set the machine to vended laundry according to the installation manual.
Wiring diagram
No. | AW PRO310 or higher | Wiring diagram |
---|---|---|
1 | Wire no. 1 | Line |
2 | Wire no. 2 | Neutral |
3 | Wire no. 3 | Terminal AA4 - 3 - WHITE (split) |
4 | Wire no. 4 | Not in use |
5 | Wire no. 5 | Terminal AA3 - 2 |
6 | Wire no. 6 | Terminal AA3 - 1 |
7 | Wire no. 7 | Terminal AA4 - 3 - WHITE (split) |
The wire installed on port 3 module AA4 is split, and the part going to the module is connected to 7 in the airwallet box and the other part is going to 3 in the airwallet box.
Attention: Move wire no. 5 from port 10 to port 7 in the Airwallet box
Updated on: 04/12/2024
Thank you!